BNWAS and Anti-Collision Alert Systems
SOLAS requires BNWAS operational whenever under way at sea; MSC.128(75) separately defines automatic, manual ON and manual OFF modes and reserves mode and dormant-period controls to the Master.
Operational Explanation
Do not confuse the SOLAS operational requirement with automatic-mode logic linked to the heading/track control system. MSC.128(75) provides automatic, manual ON and manual OFF; mode and dormant-period controls are protected and accessible to the Master. Testing and maintenance follow maker, PMS/SMS, flag/class and survey instructions.
Regulatory Reference
SOLAS V/19: BNWAS operational whenever the ship is under way at sea. MSC.128(75): modes, dormant period, alarm sequence, reset, security and malfunctions.
Scope of Application
Ships subject to the carriage requirement under relevant dates and thresholds. A full-sequence test is ship procedure/good practice where prescribed, not a universal IMO periodicity.
Procedure / How to Complete It
- Verify that the selected mode makes BNWAS operational under way at sea.
- The Master sets/protects mode and dormant period under the SMS and conditions.
- Test sequence, reset points and remote alarms under maker, PMS/SMS and statutory instructions.
- Do not simulate main-power failure unless procedure and maker authorise it.
- Record tests, defects, isolation and corrective action under the ship's system.
Practical Example
Autopilot disengaged does not mean BNWAS is not required: when under way at sea the system must be operational in the appropriate mode.
What Typically Goes Wrong
Presenting under way and autopilot as alternative triggers or inventing a uniform IMO periodicity for end-to-end/power-failure tests.
Common Mistakes Mistake Library
| Mistake | Consequence | How to Avoid It |
|---|---|---|
| Presenting under way and autopilot as alternative triggers or inventing a uniform IMO periodicity for end-to-end/power-failure tests. | Incorrect operational decision or regulatory status | Use the primary reference and ship-specific procedure |
What the PSCO Checks
Operational Tips
- Separate SOLAS requirement, equipment mode and maintenance regime.
- Test without compromising the watch.
- Do not leave mode/dormant controls open to unauthorised personnel.
Preparation checklist
- Operational under way at sea
- Appropriate mode selected
- Controls reserved to Master
- Tests under maker/PMS/SMS
- No unauthorised power-failure simulation
- Defects recorded
FAQ
Related Topics
Last substantive revision of this page: 31 August 2026 · page fingerprint c9ace3905f9d