Operational guide · Operational procedure

Reefer Container Monitoring

Telematics monitors and alerts: it does not authorise crew to change set point, ventilation, humidity or atmosphere settings without documented instructions or an approved emergency procedure.

reeferrefrigerated containerscold chainmonitoring

Operational Explanation

Refrigerated containers (reefers) carry perishable or pharmaceutical goods that require a constant temperature (set point) to be maintained for the entire duration of the voyage: any prolonged interruption of the electrical supply or of the cooling unit's operation can irremediably compromise the commercial value of the cargo.

Monitoring relies on two complementary approaches: stand-alone data loggers installed inside the container, which record temperature at regular intervals but require physical retrieval of the device for data analysis, and telematics systems integrated into the cooling unit, which transmit data in real time via cellular or satellite network and allow remote temperature adjustment.

The industry trend is towards continuous, structured electronic records with no gaps, replacing traditional periodic manual checks: this reduces the risk of gaps in temperature traceability, which is particularly critical for the pharmaceutical cold chain.

Regulatory Reference

No Convention governs cargo temperature monitoring. It is worth saying so plainly, because this page pointed to “requirements applicable through SOLAS” without naming a regulation, and no regulation on set point exists.

What SOLAS does govern is the ship's electrical installation feeding the reefer sockets: SOLAS regulations II-1/40-45 on electrical installations, main and emergency power and protection against electrical hazards. Where the reefer sockets are in a hold or an enclosed space, the fire protection requirements of Chapter II-2 for that space apply as well. Construction of the thermal container follows ISO 1496-2; securing and handling follow the CTU Code (IMO/ILO/UNECE, MSC.1/Circ.1497). Where the reefer carries dangerous goods, the applicable regime is the IMDG Code, with the Part 7 stowage provisions for temperature-controlled substances.

The rest is contract. Set point, tolerances, ventilation, recording frequency and the consequences of a deviation are fixed by the shipper's instructions and by the bill of lading; for pharmaceutical products the WHO Good Distribution Practices apply, which are World Health Organization recommendations and become binding only through national law or contract.

Scope of Application

Every container ship or multipurpose ship with reefer plugs on board, for the carriage of perishable goods, pharmaceuticals or other temperature-controlled cargo in refrigerated containers.

Procedure / How to Complete It

  1. At loading check connection, settings and shipper instructions.
  2. Monitor and record at the frequency prescribed by contract, carrier procedure and SMS; daily is only an example.
  3. Investigate alarms and restore power or technical functionality under authorised procedures.
  4. Do not change set point, ventilation, humidity or atmosphere settings without documented instruction from the authorised party, except under an already approved emergency procedure.
  5. For every authorised change record request, authorisation, time, old/new setting and confirmation.

Practical Example

A telematics alarm shows temperature out of range. Crew check power and unit under the SMS, inform the authorised party and change the set point only after documented instruction, recording old value, new value and time.

What Typically Goes Wrong

Confusing technical remote-adjustment capability with contractual authority to change settings, or imposing a daily check where a continuous system or contract prescribes another frequency.

Common Mistakes Mistake Library

MistakeConsequenceHow to avoid it
Daily temperature checks recorded generically, without a time stampInability to demonstrate the real extent of a deviation in case of a disputeRecord checks and alarms with a precise time and details of the cause
Temperature alarm detected but not promptly investigatedA prolonged deviation not corrected in timeInvestigate and correct every temperature alarm immediately upon detection
Data logger log not retrieved or not retained after dischargeNo documentary evidence in the event of a commercial disputeAlways retrieve and archive the temperature logs before returning the container

What the PSCO Checks

Reefer monitoring is not typically subject to direct PSC verification, but the reliability of the ship's electrical supply for the reefer plugs may be checked as part of the general checks on the ship's electrical system.

Operational Tips

Preparation checklist

FAQ

Does telematics let crew change temperature autonomously?
No. Remote adjustment is a controlled capability; documented authority under contract and procedure is required, except under an approved emergency procedure.
Must checks always be daily?
No. Frequency follows shipper instructions, contract, carrier procedure and SMS; it may be continuous.
What may be restored immediately?
Power and technical functionality under authorised procedures; cargo settings require the specified authority.