Fire Safety of Onboard Battery Rooms (BESS)
BESS response follows the approved emergency plan and installed design: alarm, segregation only as designed, ventilation control and approved fixed suppression/cooling from a safe position; no entry until explosion/toxic risk is assessed and authorised.
Operational Explanation
BESS response follows the approved emergency plan and installed design: alarm, segregation only as designed, ventilation control and approved fixed suppression/cooling from a safe position; no entry until explosion/toxic risk is assessed and authorised.
Regulatory Reference
Approved flag/class design and SMS; EMSA BESS Guidance is non-mandatory; SOLAS II-2/17 only where it is the actual alternative-design route.
Scope of Application
Training, familiarisation and drills to the extent required by approved design, risk assessment, flag/class and SMS; not automatically every drill for every hybrid ship.
Procedure / How to Complete It
- From a safe position raise alarm and identify the event.
- Stop/segregate only as designed.
- Control ventilation and activate the approved fixed strategy.
- Do not generically apply water or electrical isolation.
- Prohibit entry until explosion/toxic-atmosphere risk is assessed and entry authorised.
- Integrate hazards into training/drills under the approved regime.
Practical Example
The plan may use water-based, inerting or combined means: the team uses the installed system and does not enter merely because visible flame has ceased.
What Typically Goes Wrong
Imposing massive and prolonged cooling, improvising isolation/water, entering before risk clearance, or treating EMSA/drills as universally mandatory.
Common Mistakes Mistake Library
| Mistake | Consequence | How to Avoid It |
|---|---|---|
| Imposing massive and prolonged cooling, improvising isolation/water, entering before risk clearance, or treating EMSA/drills as universally mandatory. | Non-compliant decision or treatment | Follow the approved arrangement and applicable sources |
What the PSCO Checks
Operational Tips
- Separate current requirement, class/maker, SMS and voluntary guidance.
- Do not improvise tests, thresholds or intervals.
- Record deviations and corrective action.
Preparation checklist
- Approved response plan
- Remote safe controls
- Ventilation/suppression design
- Explosion/toxic entry gate
- Approved training scope
- EMSA non-mandatory
FAQ